ALARMS-MAXIMUM-PER-DEFINITION

(server version 4.06 or later)

 

                (Default = 100)

ALARMS-MAXIMUM-PER-DEFINITION  <value16>                                            

                                                                         

Specifies the maximum number of Alarms that a single definition is allowed to generate.

 

This value is primarily a protection mechanism to prevent a single definition from generating an excessive number of Alarms. Once the limit is reached, a special 'really red' or purple alarm is displayed and further alarms from the definition are disabled. Update the Alarm definition to 'reset' or clear the 'really red' alarm.    

                                                                       

Example:                                                              

                               == Alarms maximum / DEF 175    

ALARMS-MAXIMUM-PER-DEFINITION 175